[. . . ] We're pleased that you've placed your confidence in the GE brand. When operated and maintained according to the instructions in this manual, your home generator will provide many years of dependable service. This manual contains safety information to make you aware of the hazards and risks associated with home standby generators and how to avoid them. Because we do not necessarily know all the applications this equipment could be used for, it is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment. [. . . ] The exerciser will need to be re-set if the 15 Amp fuse is removed or changed, or if the starting battery is disconnected. If you want to change the day and time the unit exercises, simply perform the "Set Exercise" procedure at the exact weekday and time you want it to take place. On that day and time, press and hold "SET EXERCISE" for three seconds. The "Set Exercise" display will illuminate then turn off to confirm that the exercise timer has been set. Once the exercise cycle is complete, the unit will turn off and "Set Exercise" will no longer be displayed. The exercise cycle may be discontinued at anytime by turning the System Switch to OFF. The unit will then start and run it's 20 minute exercise cycle weekly. Before performing any generator maintenance, always perform the following steps: 1. Disconnect power before servicing control panel by removing the fuses from the transfer switch. The generator may have to run for long periods of time with no operator present. For that reason, the system is equipped with sensors that automatically shut down the generator in the event of potentially damaging conditions, such as low oil pressure, high temperature, over speed, and other conditions. the generator's control panel has a digital display that shows fault codes , like "FC_1". The table below lists the detected fault, the fault code as displayed on the control panel. The operator must reset the fault detection system each time it activates. to do so , place the control panel system switch in the OFF position for 30 seconds or more. Remedy the fault condition, then return the home generator to service by placing the system switch in the AUTO position, installing the 15 Amp fuse (if removed), and resetting the exercise timer. Fault Description Low battery voltage Low oil pressure Low voltage Engine does not start Low frequency Engine overspeed High temperature Transfer switch fault This fault is indicated by fault code FC_1. This condition occurs if the generator cannot start because the starting battery output power is below that needed to crank the engine. Causes for this problem may be a faulty battery or battery charge circuit. reinstall the battery (replace if necessary - see Battery in Final Installation Considerations in the installation manual). The unit is equipped with an oil pressure switch that uses normally closed contacts held open by engine oil pressure during operation. Should oil pressure drop below the 8 psi range, switch contacts close and the engine is shut down. [. . . ] 4 years or 1, 600 hours, whichever comes first None None None For purposes of this warranty, "Prime Power" is defined where the generator is a source of power where no electrical power is available from the UTILITY POWER GRID. If no UTILITY power is available, the generator is considered the prime power source. No part of this material may be reproduced or transmitted in any form without the express written permission of Briggs & Stratton Power Products Group, LLC. We welcome warranty repair and apologize to you for being inconvenienced. [. . . ]